ETAP 5.0 - New Features & Capabilities
 


Click here to request demo CD.

 


ETAP 5.0 - A New Milestone for Power System Analysis

ETAP 5.0 includes new modules, new major elements, existing elements modified and/or enhanced, added features to all modules, modules with major enhancements, new and enhanced libraries, and enhancements to the base module (one-line diagram).

Be sure you are up-to-date with your ETAP Upgrade and Support Agreement. The agreement interval is 12 months and includes: upgrades and new releases (including ETAP 5.0), unlimited software support, unlimited engineering support, full access to OTI’s engineering expertise by your entire engineering staff, and full credit on any license upgrades.

Click here to view ETAP 5.0 System Requirements.

ETAP 5.0 New Features Brochure (PDF)

Please contact sales@etap.com or (800) 477-ETAP[3827].



ETAP Star (Device Coordination & Selectivity) --- New Module

With ETAP Star, not only can you work with the time-current curves, you can also determine the operating time of protective devices simply by placing a fault on the one-line diagram. ETAP Star is an advanced concept in performing steady-state and dynamic coordination and selectivity of protective devices. This is achieved by utilizing intelligent one-line diagrams, comprehensive device libraries, and an integrated three-dimensional database. Designed and developed by OTI, Star is a fully integrated module within ETAP, with built-in analyses such as short-circuit and motor acceleration.

ETAP Star Features Inc.de:

  • Graphically Adjustable Device Settings
  • Sequence-of-Operation of Protective Devices
  • Embedded Fault & Motor Acceleration Analyses
  • Extensive Device Library (Verified & Validated)
  • Phase & Ground Coordination Modes
  • Multi-Function Universal Relays (50/51 P, N, G, SG, 51V, 67, 46, & more)
  • Built-In Interface with Relay Hardware
  • Display Actual Relay Transient Response
  • User-Definable Device Library Database
  • Fixed Point / Damage Curve Modeling
  • Graphical Time-Difference Calculator
  • Automatic Current & Voltage Scaling of TCC View
  • Advanced Curve-Fitting Algorithms
  • Auto Clipping for All Protective Devices
  • Click & Drag Curves to Adjust Settings
  • Automatic Layout of the One-Line Diagram in Star View
  • Print or Plot on Multiple Pages
  • Automatically Shrink to Fit on a Single Page
  • Print or Plot to Various Paper Sizes, Inc.ding Full Size Plotters
  • Print Comprehensive Reports of Input Data & Study Results
  • Customizable Print Functionality, Legends, & Device Labeling
  • Display Input Data & Study Results on the Drawing



Star Sequence-of-Operation
--- New Concept

ETAP Star Sequence-of-Operation provides a system wide solution for accurate and realistic operating times and states of protective devices, such as relay, fuse, circuit breaker, trip devices, contactor, etc. The operation time is calculated for each protective device based on its settings, time current characteristics, and interlocks for a specified fault location and type. Automatically calculate and display the fault current contributions on the one-line diagram.

  • Graphically place a fault anywhere on the one-line diagram
  • Determine the operating time of all protective devices based on the actual fault current contribution flowing through each individual device
  • Globally view post fault actions and associated operating time via a tabulated Event Viewer
  • Graphically examine the operation of protective devices via the one-line diagram


 

 



Optimal Capacitor Placement
--- New Module

Optimal Capacitor Placement allows engineers to strategically place capacitors for voltage support and power factor correction while minimizing installation and long-term operation costs. The advanced graphical interface gives users the flexibility to control the capacitor placement process and graphically view the results. The precise calculation approach automatically determines the best locations and bank sizes. In addition, it reports the branch capacity release and the estimated savings during the planning period due to var loss reduction.

  • Best Location & Bank Size
  • Minimum Total Installation & Operation Cost
  • Voltage Support & Power Factor Correction
  • Branch Capacity Release & Cost Savings
  • Capacitor Control Method
  • Review Capacitor Impact on the System



Unbalanced Load Flow
--- New Module

A robust and efficient power flow solution method must be able to model special features of distribution systems with sufficient accuracy. With ETAP’s Unbalanced Load Flow module, you can easily model your unbalanced system with detailed representation of component unsymmetrical characteristics. Accurate and reliable per-phase results are available to describe your system’s unbalanced operating conditions. Automatic alarms/warnings and advanced features such as the automatic line constant calculator make it the most advanced Unbalanced Load Flow program available today.

  • Advanced Current-Injection Method
  • Looped & Radial Systems
  • 1-Phase, 2-Phase, & 3-Phase Unbalanced Load Flow
  • Unbalanced Branch & Load Modeling
  • Transmission Line Coupling
  • Charging Current for Open-End Branches
  • Phase & Sequence Voltage, Current, & Unbalanced Rates
  • Multiple Demand Factor Non-Linear Loads
  • Real & Reactive Power Losses & Voltage Drop Calculation
  • Line & Cable Temperature Correction
  • Automatic Alert for Device Evaluation



Control System Diagram
--- New Module

ETAP seamlessly integrates power and control systems within one electrical analysis program. The Control System Diagram (CSD) simulates the sequence-of-operation of control devices such as solenoids, relays, controlled contacts, multi-sequence contacts, and actuators including inrush conditions. CSD has the capability to determine pickup and dropout voltages, losses, and current flows at any time instance as well as overall marginal and critical alerts. A large library of equipment enables engineers to quickly model and simulate the action of relays associated with control interlocks after time delays.

  • Drag & Drop Control Relays, Solenoids, Contacts, Cables, etc.
  • Control Logic Simulation (Relays, Circuit Breakers, Contacts, etc.)
  • Voltage Drop Calculation including Inrush Currents
  • Battery Discharge Calculations using Actual Control Logics
  • Automatic Alert for Pickup & Dropout Voltages
  • Automatic Overloading Alerts
  • Fully Integrated with One-Line Diagrams
  • Comprehensive Device Library (Verified & Validated)




GIS Map (Geographic Information System)
--- New Module

ETAP GIS Map superimposes electrical one-line diagrams with the corresponding geographical maps of power generation, transmission, and distribution systems. Synchronize relevant electrical equipment information from GIS into ETAP and maintain the relationship between them.

  • Data Synchronization with GIS
  • Embedded Load Flow & Fault Analyses
  • Display Analysis Results on GIS Maps
  • Display Unlimited GIS Presentations
  • Perform Add, Modify, or Delete Actions
  • View ESRI ArcGIS® Maps in ETAP
  • Use Map Tools – Zoom In, Zoom
  • Out, Full Extent, Pan, etc.
  • Fully Control Analysis Results
  • Displayed on the GIS Map
  • Map GIS Equipment Attributes to
  • ETAP Element Attributes
  • Perform Data Consistency Checks



Transmission Line
--- New Module

The new Transmission Line editor provides new configuration templates for automatic calculations of line constants. You can enter the line data or select from the newly-added transmission line library, for phase conductors and ground wires. The editor calculates conductor ampacity-temperature relationships, and sag and tension-temperature relationships of overhead transmission lines.




Line Ampacity
--- New Module
  • Line Ampacity Derating
  • Conductor Operating Temperature Calculation
  • Wind Speed & Direction Elevation, Latitude, Sun, & Solar Effects Absorptivity & Emissivity
  • Ambient & Operating Temperatures


 

 

 

 




Sag & Tension
--- New Module
  • Multiple Suspension Spans Between Dead-End Structures
  • Multiple Spans of Unequal Lengths
  • Wind, Temperature, Ice, & k Factor Effects

 

 

 

 

 




ETAP Wizard
--- New Module

ETAP 5.0 includes a time saving project management tool known as the ETAP Wizard, which enables you to record and automatically run hundreds of different studies at any time. The ETAP Wizard consists of a Scenario Wizard, a Study Wizard, and a Project Wizard.

  • Manage & Automate Studies for Multiple Projects
  • Save Study Parameters & Settings
  • Run Multiple Scenarios On-Demand
  • Use Macros to Automate & Repeat Studies



New Elements

  Static Var Compensator (SVC)
  • Capacitive & Inductive Characteristics
  • Modeling Within & Outside Control Range
  • Full Controller Dynamic Modeling
  • Several Typical Control Models High Voltage DC
  • transmission Link (HVDC)
    Load Flow Modeling
  • Different Combination of Operating Modes for Rectifier & Inverter
    Full AC/DC Controllers Dynamic Modeling
  • Current, Power, & Voltage Controllers for Rectifier & Inverter
  • Voltage-Dependent Current-Order Limits (VDCOL) Control Model
  • Shut-Off & Re-Start Models
 
  High Voltage DC Transmission Line (HVDC)
  • Load Flow Modeling
  • Different Combination of Operating Modes for Rectifier & Inverter
  • Full AC/DC Controllers Dynamic Modeling
  • Current, Power, & Voltage Controllers for Rectifier & Inverter
  • Voltage-Dependent Current-Order Limits (VDCOL)
  • Control Model
  • Shut-Off & Re-Start Models
  Multi-Function (Universal) Relay
  • Multi Level & Function
  • Overcurrent (50/51)
  • Voltage Control/Restraint (51V)
  • Phase, Neutral, Ground, Sensitive Ground, & Negative
  • Sequence
  • Directional Overcurrent (67)
  • Overload (49)
  • Multiple CT & PT Connections
  • Multiple Circuit Breaker Interlocks
 
  Overload Heater & Relay
  • In-Line, CT Connected, & Solid State
  • Minimum & Maximum Resistances
  • Automatic Voltage Drop Calculation for Connected Loads
  • Resistance Tolerance
  Text Box
  • Graphically Display Text & Element Properties
  • Automatic Updates with Change of Properties
  • Display on One-Line Diagrams, Underground Raceway Systems,
  • Control System Diagrams, Star Views, etc.
 
  Grounding Elements
  • Intelligent One-Line Diagrams
  • Generators, 2W & 3W Transformers
  • Connect Instrument Transformers, Relays, & Meters
  • Hide& Show On-Demand per Presentation
 

Enhanced Elements
  Generator
  • Generation Category • PF Control Mode
  • MW-Mvar Capability Curve • Xd” Tolerance
  • Inertia Calculator (Prime Mover, Coupling Gear, & Generator)
  • Shaft Torsion Parameters • Engine Rating
  • Grounding Through Distribution Transformer
  • Graphical Grounding Elements on One-Line Diagram
 
  Power Grid
  • Generation Category
  • PF Control Mode
  Bus
  • Arc Flash Parameters Based on Normal kV
  • Unbalanced Initial Voltage
  • Arc Flash Calculator with Embedded Fault Analysis & Protective Device Clearing Time
 
  Lumped Load
  • Unbalanced Loading
  • Dynamic Model
  • Voltage & Frequency Dependent Models (Exponential, Polynomial, & Comprehensive)
  Induction & Synchronous Motors
  • Inertia Calculator (Motor, Coupling Gear, & Load)
  • Shaft Torsion Parameters
  • Point-by-Point Load Model
  • Partial-Winding, Y-delta, Rotor External Impedance, & Soft Starters (Current, Voltage, & Torque Control)
 
  Transmission Line
  • Multi-Distance & Multi-Line Coupling
  • Tower Arrangement with Multiple Templates
  • User-Defined Conductor Configurations
  • Transposition & Multi-Layer Earth
  Transformer (2W & 3W)
  • Grounding Through Distribution
  • Graphical Grounding Elements on One-Line Diagram
  • Transformer (2W & 3W)
   


Enhanced Modules

Added Features to All Modules
Thanks to user feedback, significant additions and improvements have been made to enhance all network analyses modules. These enhancements include various study options to globally change and adjust system parameters and topology with a click of the mouse to increase your productivity.

  • Individual and/or Global Tolerance (Length and/or Impedance) for Cables,
  • Transmission Lines, OLH, Transformers, & Reactors
  • Isolated Subsystem Index
  • Parameter Adjustment Report
  • Generation Category
  • Transmission Line Coupling
  • Protection Page (Cable, Transmission Line, Transformer, Generator, Induction Motor, Synchronization Motor)
  • Charging Current for Single-End Open Branches (Cable, Transmission Line, & Impedance Branch)
  • New One-Line Diagram Zoom
  • Enhanced Connection Logic for One-Line Diagram
  • UPS Output Connection

Short-Circuit

We have enhanced the IEC Standard for device evaluation based on maximum fault current through protection devices, and reporting of braking current as a function breaker time delay. ETAP 5.0 also provides detailed reports and graphical display of line-to-ground, line-to-line, and line-to-line-to- ground fault currents.

 

 

 

 

Arc Flash


ETAP Arc Flash Analysis estimates the arc flash incident energy under a bolted 3-phase short circuit fault and determines the flash protective boundary to live parts for shock protection. Design safer power systems by insuring compliance with OSHA 29 CFR 1910.132(d) 1990, NFPA 70E-2004, and IEEE 1584-2002 Standards.

  • System Calculated or User-Defined Fault Current
  • System Calculated or User-Defined Arcing Fault Clearing Time (Interface with ETAP Star)
  • System Calculated or User-Defined System Grounding
  • Arcing Current Variation
  • Automatic Determination of Hazard/Risk Category for PPE
  • Create Regulation Arc Flash Hazard Labels for Every Bus
  • Different Label Templates Available for Each Faulted Equipment
  • Quick Inc.ent Energy Calculator (Bus Arc Flash Page)
  • User-Defined Equipment Gap Between Conductors & X Factors
  • Limited Approach Boundary Based on NFPA 70E Table 2-1.3.4
  • Added Arc Flash Calculation Icons to the Short-Circuit Toolbars
  • Automatically Update Arc Flash Analysis Results to Every Bus


Load Flow

ETAP’s advanced Load Flow module includes features such as automatic device evaluation, summary alarms/warnings, and intelligent graphics. Already a robust power calculation tool, the module has enhanced device evaluation, alerts, and reporting.


 

Motor Acceleration

The Motor Acceleration module has been enhanced to reduce the time it takes to conduct single and group motor acceleration studies. Major enhancements include the new soft starters (control motor voltage, current, or torque), alerts (report various violation for motors, buses, generators, and engines), unlimited time events, and user-defined point-by-point motor load modeling features.

  • Partial-Winding, Y-delta, Rotor External Impedance, & Soft Starters
  • Comprehensive Alert View
  • Unlimited Number of Events
  • Point-by-Point Motor Load Model
  • Plots for Static Loads & Buses
  • Source Voltage Sequencing

Transient Stability

The Transient Stability module has been dramatically expanded to increase the type of transient actions (disturbances, load and generation changes, relay actions, etc.) you can place on the system. Among the many added features are SVC, multi-mass shaft modeling, synchronous motor acceleration with discharge resistor, and automatic assignment of reference machine for each isolated subsystem.

  • Partial-Winding, Y-delta, Rotor External Impedance, & Soft Starters
  • Motor Point-by-Point Load Model
  • HVDC Transmission Link
  • Dynamic Model for Lumped Load
  • Universal Relay Actions
  • SVC (Steady-State & Transient Response)
  • Transformer LTC Initial & Operating Time Delays
  • Enhanced General Models for Lumped Load
  • Synchronous Motor Acceleration with Discharge Resistor & Pull-in Process
  • Step & Ramp Changes of Generation Level, and AVR Reference Voltage
  • Step & Ramp Changes of Synchronous & Induction Motor Loading
  • Enhanced Fractional Branch Faults (Transmission Line, Cable, & Impedance)
  • System Zoning & Automatic Reference Machine Assignment for Each Islanded Subsystem
  • New Plots
    - Absolute Power Angle for Synchronous Generators & Motors
    - Generator & Motor Mvar Flows
    - Terminal Voltage for Synchronous & Induction Motors
    - Difference of Variables for Fast Bus Transfer
  • Contactor Open & Close Action
  • Start Synchronous & Induction Motors by Starting Category
  • Multi-Mass Shaft Model for Generators & Motors
  • New Bus Frequency Calculations using Electrical Distance Method

Harmonics

The new Harmonic Analysis module helps you quickly identify problems, reduce nuisance trips, design and test filters, and distortion limit violations alerts. The module provides comprehensive load flow and frequency scan calculations using detailed harmonic models and non-integer harmonic filters.

  • New Harmonic Filters
  • Transformer k Factor Rating
  • Alerts for VTHD, VIHD, Transformer, Filter, Capacitor, & Cable
  • Report Resonance Frequencies & Magnitudes
  • Enhanced General Models for Lumped Load
  • One-Line Display of Capacitor & Filter Current
  • Generation of Harmonic Sources Based on Device Parameters for VFD, UPS, Charger, & Inverter

 

 

 

Real-Time (PSMS)


Built on ETAP, the world-leading power system analysis software, ETAP Real-Time is a real-time energy management system used by operators and managers to monitor, control, and optimize power systems.

  • Enhanced State Estimator & Load Distribution
  • PF Meters
  • New Real-Time Simulation Modules
  • Enhanced Intelligent Load Shedding
  • Extended Communication Protocols


 

Libraries (New & Enhanced)

OTI has enhanced and created many new libraries with data locking and checker capabilities. Also for ETAP 5.0, all libraries related to protective devices are combined (short-circuit ratings and time current characteristics) into one ETAP library. The new library has been validated and verified based on published manufacturer data per ETAP’s quality assurance program.

  • Control Relay
  • Solenoid
  • LV Circuit Breaker
  • Fuse
  • Overload Relay & Heater
  • Point-by-Point Motor Load Characteristics
  • Transmission Line Library (Phase & Ground Conductors)
  • Trip Devices (Solid State, Thermal-Magnetic, Electro-Mechanical, & Motor Circuit Protector)
  • Multi-Function (Universal) Relay (50/51 P, N, G, SG, 51V, 67, 46, …)




Click here to view all ETAP Modules.

Click on the release version below to view new features and capabilities for that version:

 
 
 
 


2008 版权所有
美国欧特艾远东(南京)计算机技术有限公司 是美国OTI公司全球唯一的分公司,OTI是ETAP产品的研发生产商..
推荐使用IE4.0版本以上浏览器,1024X768屏幕分辨率浏览此页面.
推荐使用IE4.0版本以上浏览器,1024X768屏幕分辨率浏览.